Vertical Commercial Water Boiler

Vertical Commercial Water Boiler

Thermal power: 99KW

Thermal efficiency: >98%

Introduction: To satisfy commercial customers, the demand of the volume type small and medium sized hot water boiler, we quickly introduced a gas hot water heater with advanced condensing technology. The elegant appearance, easy operating page and unique structural design will make better service for the users. V serious has been widely used in all kinds of heating of building, rebuilding, hot water engineering.

 Chat Online Messages Email

Features

01

Automatic Control

Fully automatic control and complete functions. Once come into use, the boiler automatically operates, automatically regulates the water level and water temperature, and automatically protects.

02

High Efficiency

This vertical boiler has a waste heat using method and that makes the thermal efficiency can be as high as 98%. The product exhaust temperature can be reduced to 60℃.

03

Low Pollution

Benefiting from the efficiency of the boiler plays to its limit, this boiler has a comprehensive function of pollution solution. That leads a substantial reduction in emissions of harmful substances such as NOx.

Product profile and dimension drawing

Parameterss

Operating conditions Water inlet/outlet temperature70℃/90℃ Water inlet/outlet temperature 60℃/80℃
Thermal efficiency(%) Gas consumption(m³/h) Outlet smoke temperature(℃) Thermal efficiency(%) Gas consumption(m³/h) Outlet smoke temperature(℃)
V6-99 97.2 9.58 81.2 98.4 9.467 66
V5-99 97.2 9.58 81.2 98.4 9.467 66
Operating conditions 50℃/60℃
Inlet/outlet
temperature
30℃/40℃
Inlet/outlet
temperature
Thermal efficiency(%) Gas consumption(m³/h) Outlet smoke temperature(℃) Thermal efficiency(%) Gas consumption(m³/h) Outlet smoke temperature(℃)
V6-99 101.8 9.15 57.9 104.4 8.923 40.5
V5-99 101.8 9.15 57.9 104.4 8.923 40.5
Circulating water (L/h)The relative warming of the thermal water rate
25℃ 35℃ 65℃
V6-99 3406 2433 1310
V5-99 3406 2433 1310
The performance parameters NOx (mg/Nm³) Water volume (L) Electric power (W) Net weight(kg) With water weight (kg) Rated working pressure (Mpa) Gas outlet (mm) Gas pressre(pa) Relief valve (mm) Safety valve pressure (MPa) Drain outlet (mm) Water inlet/outlet (mm) Inlet/outlet Smoke outlet (mm)
V6-99 <30 495 <390 620 1195 1.0 DN20 2-3000 DN25 1.1 DN20 DN50 Ф110
V5-99 <80 495 <390 620 1195 1.0 DN20 2-3000 DN25 1.1 DN20 DN50 Ф110

Take 38.3MJ/Nm³ as the low calorific value of natural gas

As the technology is constantly updated, it is subject to change without notice. For detailed parameters, please refer to the headquarters of Fangkuai Boiler co., LTD.

MESSAGES